Steel melting furnace dedusting
To condition the exhaust gas temperatures of 4 electric steel melting furnaces, 4 exhaust gas tube coolers are installed upstream of the bag filter systems in order to lower the temperature of the hot raw gases from the furnace extraction to the maximum permissible filter temperature (approx. 140-150 °C).
For this purpose, the heat exchanger tube bundles are flushed with atmospheric ambient cooling air in a cross flow, which is conveyed by a total of 6 axial fans per cooler.
At full load, each heat exchanger generates a cooling air volume flow of almost 1 million cubic meters per hour.